What You Need to Know
Thirty
years ago, something unexpected was discovered about the fluids
used in air conditioners. Once they get into the air, they
stay there a long time. Not much happens to them until they
gradually diffuse several miles high, into the stratosphere.
At that point, unshielded sunlight breaks them down. It turns
out that they have a devastating effect on the ozone layer.
A little bit of air conditioning fluid vapor destroys a lot of ozone,
through a chain reaction. When that happens, the ultraviolet
(burning) rays from the sun can reach the earth, a condition that
greatly increases the risk that you and your kids will get skin
cancer from being out in the sunshine. It's hard to believe
that being sloppy with refrigerants can have that drastic an effect,
but there is no longer any doubt.
As
a result, refrigerants (collectively called chlorofluorocarbons
– CFCs) are now tightly regulated. Refrigerant removal must
be done with acceptable equipment, by certified technicians, and
must be handled and recycled properly. The used filters from
the operation must be treated as a hazardous waste.
You also need to keep records.
This
fact sheet will outline the special rules that apply to refrigerant
recovery and handling, and will give you links to more detailed
information.
Regulations
Refrigerants (Freon, R-12, R-22, R-134a) are the chemicals used
in vehicle air conditioning. By the end of 1995 all manufacturers
were required to stop production of R-12. However, the use of R-12
is still permitted until supplies are depleted.
Federal
regulations state that it is illegal to vent any refrigerant to
the environment during repair, service, maintenance, recycling or
disposal of refrigeration and air conditioning equipment because
of the harmful effect of these chemicals on our atmosphere.
Refrigerants
must be processed using one of the following methods:
- Recovery
–
removing refrigerant from air conditioning units and storing
it in a container without testing or processing it; or
- Reclaiming
– processing refrigerant, usually by distillation, until
all impurities are removed and it meets resale specifications.
Spent
refrigerants that are not reclaimed or recycled are regulated wastes.
EPA requires use of certified refrigerant recycling equipment when
servicing vehicle air conditioners. Anyone in Missouri who works
on vehicle air conditioning systems must also be certified by an
EPA-approved organization. Each facility must either have a certified
person on-site or bring in a person certified to perform this work.
Refrigerant
Recovery. The rules for recovery depend on
whether the refrigerant will be sent off-site to a reclamation facility
or to a MVAC service center for reuse without prior reclamation.
If
the refrigerant will be sent off-site to a reclamation facility,
then refrigerant must be recovered using equipment that reduces
the system pressure to 102 mm (4 inches) of mercury vacuum. There
is no restriction on who performs the recovery. That person does
not need to be a certified technician.
If
the refrigerant will be sent to an MVAC service facility for charging
or recharging into an MVAC or MVAC-like appliance without prior
reclamation, then the same rule applies, but there is a further
restriction. Prior to such charging or recharging, the refrigerant
must be recovered using approved refrigerant recycling equipment
dedicated for use with MVACs and MVAC-like appliances. The recovery
process must be performed either by a certified technician, or by
an employee, owner, or operator of, or contractor to, the auto recycling
facility.
Storage
of Refrigerant. Store
refrigerant in tanks that meet the federal Department of Transportation
(DOT) or Underwriters Laboratory (UL) standards. The tanks should
be labeled “Refrigerants.”
Sale
of Refrigerant. The rules for sale of refrigerant
depend on whether the refrigerant will be sent off-site to a reclamation
facility or to a MVAC service center for reuse without prior reclamation.
If
the refrigerant will be sent off-site to a reclamation facility,
then it can be sent to facilities that meet EPA standards for reclaiming
refrigerants or those that buy used refrigerant for resale to the
reclaiming operations.
If
the refrigerant will be sent to an MVAC service facility for charging
or recharging into an MVAC or MVAC-like appliance without prior
reclamation, then it must be sold to a certified technician, who
must recycle the used refrigerant before recharging into an MVAC.
Recordkeeping
and Reporting.
The following are recordkeeping and reporting requirements related
to recovery, and sale of refrigerant:
- Anyone who recovers refrigerant from MVACs or MVAC-like
appliances for purposes of disposal must certify to EPA by submitting
a section 608 form that their equipment meets refrigeration recovery
standards.
- Maintain records for 3 years showing that for each vehicle
with a air conditioning unit that refrigerants were either (1)
recovered at your facility or (2) that the vehicle was brought
into the facility free of refrigerants and that the refrigerants
were removed prior to entering your facility using proper methods.
- Anyone who sells or distributes any ozone-depleting
refrigerant must retain invoices for at least three years that
indicate the name of the purchaser, the date of sale, and the
quantity of refrigerant purchased.
Links
to the Regulations. Use
the following links to view the regulations pertaining to refrigerants.
Clean Air Act Sec. 609. Servicing
Of Motor Vehicle Air Conditioners
EPA's Final Rule Governing
Substitutes for CFC-12 Refrigerant in MVACs
EPA-Certified Refrigerant Reclaimers
Self-Audit
Checklist
When
an inspector comes to your facility, there are certain things he
or she checks to see if you are in compliance with environmental
regulations. It makes good sense for you to perform a "self-audit"
and catch and correct problems before they result in penalties.
Also, there are some compliance incentives associated with self-audits
(see Audit
Policy Page).
Use
the following list to audit your procedures for refrigerant/CFC
management.
- If the refrigerant will be sent off-site to a
reclamation facility, verify that:
- The refrigerant was recovered
using equipment that reduces the system pressure to 102 mm (4
inches) of mercury vacuum.
- A section 608 certification
form has been completed for the recovery equipment.
- The refrigerant was sold to
facilities that meet EPA standards for reclaiming refrigerants
or to a company that buys used refrigerant for resell to reclaiming
companies.
- You have retained invoices
that indicate the name of the purchaser, the date of sale, and
the quantity of refrigerant purchased.
- If the refrigerant will be sent to an MVAC service
facility for charging or recharging into an MVAC or MVAC-like
appliance without prior reclamation, verify that:
- The refrigerant was recovered
using equipment that reduces the system pressure to 102 mm (4
inches) of mercury vacuum.
- A section 608 certification
form has been completed for the recovery equipment.
- The refrigerant was sold to
facilities that meet EPA standards for reclaiming refrigerants
or those that buy used refrigerant to resell to the reclaiming
operations.
Best
Management Practices (BMPs)
Most
regulations tell you what you have to do to be in compliance, but
they don’t explain how to do it. That’s where "best management
practices" come into play. BMPs are proven methods that
help you to get into compliance and stay there.
The
following BMPs are recommended for management and recycle of refrigerant/CFCs:
- Use only approved reclaiming units when recharging or
removing refrigerants.
- Remove and recover refrigerants prior to crushing and
dismantling vehicles.
- Verify that all vehicles entering the facility without
refrigerant have had the refrigerant removed using proper methods.
- Employ certified technicians for refrigerant recovery.
- Avoid mixing R-12 and 134a since contaminated refrigerant
can’t be put back into the vehicle and must be sent to a recycling
facility.
- Do not use alternative refrigerants containing liquefied
petroleum (LP). These refrigerants not only cause contamination,
but pose a health risk due to explosions.
- Be sure to use the proper O-rings, lubricants, etc.
when retrofitting automobile air conditioning systems.
- Don’t allow Freon to mix with oil prior to reclamation
or recycling.
- Sell refrigerant to certified technicians or to certified
reclamation facilities that will reclaim the refrigerant to its
original purity specifications.
- Dispose of filters from CFC recapture as hazardous waste.
- Keep accurate records for at least 3 years.
Contacts
-
For
more information, call U.S. EPA’s Ozone Protection Program at
1-800-296-1996.