What You Need to Know
Thirty
years ago, something unexpected was discovered about the fluids
used in air conditioners. Once they get into the air, they
stay there a long time. Not much happens to them until they
gradually diffuse several miles high, into the stratosphere.
At that point, unshielded sunlight breaks them down. It turns
out that they have a devastating effect on the ozone layer.
A little bit of air conditioning fluid vapor destroys a lot of ozone,
through a chain reaction. When that happens, the ultraviolet
(burning) rays from the sun can reach the earth, a condition that
greatly increases the risk that you and your kids will get skin
cancer from being out in the sunshine. It's hard to believe
that being sloppy with refrigerants can have that drastic an effect,
but there is no longer any doubt.
As
a result, refrigerants (collectively called chlorofluorocarbons
– CFCs) are now tightly regulated. Refrigerant removal must
be done with acceptable equipment, by certified technicians, and
must be handled and recycled properly. The used filters from
the operation must be treated as a hazardous waste.
You also need to keep records.
This
fact sheet will outline the special rules that apply to refrigerant
recovery and handling, and will give you links to more detailed
information.
Regulations
Refrigerants
(Freon, R-12, R-22, R-134a) are the chemicals used in vehicle air
conditioning. By the end of 1995 all manufacturers were required
to stop production of R-12. However, the use of R-12 is still permitted
until supplies are depleted.
Federal
regulations state that it is illegal to vent any refrigerant to
the environment during repair, service, maintenance, recycling or
disposal of refrigeration and air conditioning equipment because
of the harmful effect of these chemicals on our atmosphere.
Refrigerants
must be processed using one of the following methods:
- Recovery
– removing refrigerant from air conditioning units and storing
it in a container without testing or processing it; or
- Reclaiming
– processing refrigerant, usually by distillation, until all impurities
are removed and it meets resale specifications.
Spent
refrigerants that are not reclaimed or recycled are regulated wastes.
EPA requires use of certified refrigerant recycling equipment when
servicing vehicle air conditioners. Anyone in Missouri who works
on vehicle air conditioning systems must also be certified by an
EPA-approved organization. Each facility must either have a certified
person on-site or bring in a person certified to perform this work.
Refrigerant
Recovery. The rules for recovery depend on whether the refrigerant
will be sent off-site to a reclamation facility or to a MVAC service
center for reuse without prior reclamation.
If
the refrigerant will be sent off-site to a reclamation facility,
then refrigerant must be recovered using equipment that reduces
the system pressure to 102 mm (4 inches) of mercury vacuum. There
is no restriction on who performs the recovery. That person does
not need to be a certified technician.
If
the refrigerant will be sent to an MVAC service facility for charging
or recharging into an MVAC or MVAC-like appliance without prior
reclamation, then the same rule applies, but there is a further
restriction. Prior to such charging or recharging, the refrigerant
must be recovered using approved refrigerant recycling equipment
dedicated for use with MVACs and MVAC-like appliances. The recovery
process must be performed either by a certified technician, or by
an employee, owner, or operator of, or contractor to, the auto recycling
facility.
Storage
of Refrigerant. Store refrigerant in tanks that meet the federal
Department of Transportation (DOT) or Underwriters Laboratory (UL)
standards. The tanks should be labeled “Refrigerants.”
Sale
of Refrigerant. The rules for sale of refrigerant depend on
whether the refrigerant will be sent off-site to a reclamation facility
or to a MVAC service center for reuse without prior reclamation.
If
the refrigerant will be sent off-site to a reclamation facility,
then it can be sent to facilities that meet EPA standards for reclaiming
refrigerants or those that buy used refrigerant for resale to the
reclaiming operations.
If
the refrigerant will be sent to an MVAC service facility for charging
or recharging into an MVAC or MVAC-like appliance without prior
reclamation, then it must be sold to a certified technician, who
must recycle the used refrigerant before recharging into an MVAC.
Recordkeeping
and Reporting. The following are recordkeeping and reporting
requirements related to recovery, and sale of refrigerant:
- Anyone
who recovers refrigerant from MVACs or MVAC-like appliances for
purposes of disposal must certify to EPA by submitting a section
608 form that their equipment meets refrigeration recovery standards.
- Maintain
records for 3 years showing that for each vehicle with a air conditioning
unit that refrigerants were either (1) recovered at your facility
or (2) that the vehicle was brought into the facility free of
refrigerants and that the refrigerants were removed prior to entering
your facility using proper methods.
- Anyone
who sells or distributes any ozone-depleting refrigerant must
retain invoices for at least three years that indicate the name
of the purchaser, the date of sale, and the quantity of refrigerant
purchased.
Links
to the Regulations. Use the following links to view the regulations
pertaining to refrigerants.
Clean Air Act Sec. 609. Servicing
Of Motor Vehicle Air Conditioners
EPA's Final Rule Governing
Substitutes for CFC-12 Refrigerant in MVACs
EPA-Certified Refrigerant Reclaimers
Self-Audit
Checklist
When
an inspector comes to your facility, there are certain things he
or she checks to see if you are in compliance with environmental
regulations. It makes good sense for you to perform a "self-audit"
and catch and correct problems before they result in penalties.
Also, there are some compliance incentives associated with self-audits
(see Audit Policy Page).
Use
the following list to audit your procedures for refrigerant/CFC
management.
- If
the refrigerant will be sent off-site to a reclamation facility,
verify that:
- The
refrigerant was recovered using equipment that reduces the system
pressure to 102 mm (4 inches) of mercury vacuum.
- A
section 608 certification form has been completed for the recovery
equipment.
- The
refrigerant was sold to facilities that meet EPA standards for
reclaiming refrigerants or to a company that buys used refrigerant
for resell to reclaiming companies.
- You
have retained invoices that indicate the name of the purchaser,
the date of sale, and the quantity of refrigerant purchased.
- If
the refrigerant will be sent to an MVAC service facility for charging
or recharging into an MVAC or MVAC-like appliance without prior
reclamation, verify that:
- The
refrigerant was recovered using equipment that reduces the system
pressure to 102 mm (4 inches) of mercury vacuum.
- A
section 608 certification form has been completed for the recovery
equipment.
- The
refrigerant was sold to facilities that meet EPA standards for
reclaiming refrigerants or those that buy used refrigerant to
resell to the reclaiming operations.
Best
Management Practices (BMPs)
Most
regulations tell you what you have to do to be in compliance, but
they don’t explain how to do it. That’s where "best management
practices" come into play. BMPs are proven methods that
help you to get into compliance and stay there.
The
following BMPs are recommended for management and recycle of refrigerant/CFCs:
- Use
only approved reclaiming units when recharging or removing refrigerants.
- Remove
and recover refrigerants prior to crushing and dismantling vehicles.
- Verify
that all vehicles entering the facility without refrigerant have
had the refrigerant removed using proper methods.
- Employ
certified technicians for refrigerant recovery.
- Avoid
mixing R-12 and 134a since contaminated refrigerant can’t be put
back into the vehicle and must be sent to a recycling facility.
- Do
not use alternative refrigerants containing liquefied petroleum
(LP). These refrigerants not only cause contamination, but pose
a health risk due to explosions.
- Be
sure to use the proper O-rings, lubricants, etc. when retrofitting
automobile air conditioning systems.
- Don’t
allow Freon to mix with oil prior to reclamation or recycling.
- Sell
refrigerant to certified technicians or to certified reclamation
facilities that will reclaim the refrigerant to its original purity
specifications.
- Dispose
of filters from CFC recapture as hazardous waste.
- Keep
accurate records for at least 3 years.
Contacts
- For more information, call U.S. EPA’s Ozone Protection Program
at 1-800-296-1996.