The following fact sheet was prepared by the ECAR Center staff. Once prepared, each ECAR Center fact sheet undergoes a review process with the applicable state environmental agency(ies). You can check on the status of the review process here. Please read the disclaimer on the status page. While we have tried to present a summary of the essential information on this topic, you should be aware that other items, such as local regulations, may apply to you.

What You Need to Know

Stormwater
Resource Locator
All vehicle dismantling facilities in the United States (except those in a combined sewer service area or facilities that do not discharge stormwater from their property) are required by the Clean Water Act to obtain a stormwater permit either from the U.S. Environmental Protection Agency or from an appropriate state agency. For more information on EPA’s stormwater regulations, please see:

Federal EPA National Pollutant Elimination Discharge System (NPDES) Stormwater Regulations

EPA defines automobile salvage yards and scrap recycling facilities as industries eligible to use the multi-sector general permit (MSGP). Sector M: Auto Salvage Yards

Included in this permitting process are requirements to file a Notice of Intent (NOI) with the appropriate state agency and to prepare a Storm Water Pollution Prevention Plan (SWPPP) to describe how you will address your facility’s stormwater issues. For information on how to comply with these requirements, please see:

NEW—Effective 9/29/08—
EPA’s Multi-Sector General Permit

The Clean Water Act requires virtually every automotive salvage or recycling operator to obtain a stormwater permit. The exceptions to this rule are few, and they are explained further in the detailed information provided below. Therefore, if you own or operate a salvage or recycling operation and you do not currently have a stormwater permit, you most likely are out of compliance. The purpose of this fact sheet is to help you either to get into compliance or to assist you to develop a more efficient and effective compliance strategy.

Rain or snow falling on your property can pick up contaminants as it runs off, and can carry the contaminants through drainage systems directly into streams, rivers, and lakes. The term "stormwater" refers to this type of runoff.

In 1987, Congress mandated that "industrial" sites obtain stormwater permits. In 1990, EPA defined "industrial" to include, among many other types of sites, "salvage yards and automotive [recyclers]." [Title 40 CFR 122.26(b)(14)(vi)]. These mandates apply across the country, regardless of your state. Congress and EPA took this action because stormwater that comes in contact with metals, oil and grease, used batteries and tires, and other materials common at automotive recycling facilities may cause localized pollution that can affect the local community’s ability to swim and fish in lakes, rivers, and streams.

For example, the mercury that still may be found in old automotive switches or even some new parts is toxic to humans and to the fish they may catch and eat. By obtaining a stormwater permit, and more importantly, by taking some common sense actions under the permit to prevent stormwater contamination, you can provide your community with environmental benefits to compliment the value of recycling end-of-life vehicles.

Although Congress and EPA created the national rules that provide the basic framework for stormwater regulations, the rules are implemented by the individual state environmental agencies. EPA may help certain states develop programs and it provides guidance to all states, but for the most part, you obtain a stormwater permit from your state environmental agency. Information about your state permit, compliance requirements, contact information, and other helpful hints are provided in the following pages of this site. The most important part of the compliance program is developing a stormwater pollution prevention plan, and this site will help you to develop such a plan. The key for you is to make sure that you implement the plan and adhere to your legal obligations.


Regulations

How to Get Permit Coverage. This Baseline Storm Water General Permit authorizes storm water discharges associated with industrial activity. Discharges associated with industrial activities, will require NPDES storm water discharge permits if material handling equipment or activities, raw materials, intermediate products, final products, waste materials, by-products, or industrial machinery are exposed to storm water.

This permit was issued on October 28, 2005 and expires on September 30, 2010. It replaces the previous Baseline Storm Water General Permit that expired on September 11, 2005.

Complete and appropriately signed BNOI Forms must be submitted to:

Chief, Environmental Permits Division
Mississippi Department of Environmental Quality
Office of Pollution Control
P.O. Box 10385
Jackson, Mississippi 39289-0385.

How To Obtain Authorization

  1. Owners and/or operators desiring coverage for storm water discharges associated with industrial activity under this general permit must submit a Baseline Notice of Intent (BNOI) in accordance with the
  2. Upon review of the Baseline Notice of Intent (BNOI), the MDEQ staff may recommend that coverage not be granted and/or that an alternate permit would be more appropriate. The MDEQ staff recommendations may be brought before the Mississippi Environmental Quality Permit Board (Permit Board) for review and consideration at a regularly scheduled meeting.
  3. Coverage under this permit will not be granted until all other required MDEQ permits, certifications and approvals are satisfactorily addressed.
  4. Owners or operators are authorized to discharge storm water associated with industrial activity under the terms and conditions of this permit only upon receipt of written notification of approval of coverage by the Permit Board staff. Discharge of storm water without written notification of coverage or issuance of an individual National Pollutant Discharge Elimination System (NPDES) Storm Water Permit is a violation of the Mississippi Air and Water Pollution Control Law.

How to Request Subsequent Recoverage of Reissued Permit:
Permittees requesting re-coverage under a subsequently reissued Baseline General Permit should submit their request for re-coverage on the last Annual Comprehensive Site Inspection and SWPPP Evaluation Certification report (due no later than January 28, 2010) in lieu of an application or recoverage form submittal. The submittal of the last Annual Comprehensive Site Inspection and SWPPP Evaluation Certification Form shall be deemed to be an NOI for re-coverage under a subsequently reissued Baseline Storm Water General Permit. Otherwise, a recoverage form requesting subsequent coverage under the reissued general permit must be submitted no later than the expiration date of this permit. Resubmittal of the Storm Water Pollution Prevention Plan (SWPPP) is not required if the SWPPP is on-site, current and adequately addresses the sources of pollution at the facility. If reissuance of this general permit does not occur before its expiration date and the permittee has submitted a timely and complete request for re-coverage, continued coverage under this permit will be allowed until the effective date of the reissued general permit.

Links to the Regulations and Forms. Use the following links to view the regulations pertaining to stormwater management.

Baseline Storm Water General Permit for Industrial Activities

Federal EPA National Pollutant Elimination Discharge System (NPDES) Stormwater Regulations


Self-Audit Checklist

When an inspector comes to your facility, there are certain things he or she checks to see if you are in compliance with environmental regulations. It makes good sense for you to perform a "self-audit" and catch and correct problems before they result in penalties. Also, there are some compliance incentives associated with self-audits (see Audit Policy Page).

Use the following list to audit your stormwater permit.

  1. Is your facility covered under a general permit or does your facility have an individual stormwater permit? Verify that your facility is either covered under the general permit (MSR00) or has an individual stormwater permit issued by MDEQ.
  2. Has your facility developed and implemented a stormwater pollution prevention plan? Verify that a SWPPP has been prepared, implemented, submitted to the OPC and is available onsite for inspection. Review the plan and verify that BMPs have been implemented. Update the plan when operational changes occur that impact stormwater.
  3. Has your facility conducted stormwater sampling and visual inspections? Review your records to verify that annual sampling and inspections have been performed, and the results sent to the OPC. Proof of these activities must be incorporated into your SWPPP.
  4. Has your facility maintained monitoring results and records? Verify that all monitoring and inspection records are maintained for at least three years from the date of sample collection or for the term of the permit, whichever is greater.

Best Management Practices (BMPs)

The following is a list of BMPs for auto salvage facilities identified by EPA when the stormwater regulations were published:

Dismantling and vehicle maintenance:

  • Drain all fluids from vehicles upon arrival at the site. Segregate the fluids and properly store or dispose of them.
  • Maintain an organized inventory of materials used in the maintenance shop.
  • Keep waste streams separate (i.e. waste oil and solvents). Non-hazardous substances that are contaminated with hazardous substances are considered a hazardous waste.
  • Recycle antifreeze, gasoline, used oil, mineral spirits and solvents.
  • Dispose of greasy rags, oil filters, air filters, batteries, spent coolants and degreasers properly.
  • Label and track the recycling of waste material.
  • Drain oil filters before disposal or recycling.
  • Store cracked batteries in a nonleaking secondary container.
  • Promptly transfer used fluids to the proper container.
  • Do not pour liquid waste down floor drains, sinks or outdoor storm drains.
  • Plug floor drains that are connected to the storm or sanitary sewer. If necessary, install a sump that is pumped regularly.
  • Inspect the maintenance area regularly for proper implementation of control measures.
  • Filter stormwater discharges with devices such as oil-water separators.
  • Train employees on proper waste control and disposal procedures.

Outdoor vehicle, equipment and parts storage:

  • Use drip pans under all vehicles and equipment waiting for maintenance and during maintenance.
  • Store batteries on impervious surfaces. Curb, dike or berm this area.
  • Confine storage of parts, equipment and vehicles to designated areas.
  • Cover all storage areas with permanent cover (roof) or temporary cover (canvas tarps).
  • Inspect the storage yard for drip pans and other problems regularly.

Vehicle, equipment and parts washing areas:

  • Avoid washing parts or equipment outside.
  • Use phosphate-free biodegradable detergents.
  • Consider using detergent-based or water-based cleaning systems in place of organic solvent degreasers.
  • Designate an area for cleaning activities.
  • Contain steam cleaning washwaters or discharge under an applicable NPDES permit.
  • Ensure that washwaters drain well, and are not draining into a MS4 or surface water body.
  • Do not discharge wastewater into a dry well.
  • All discharges authorized by the general stormwater permit must fully meet all applicable water quality standards.
  • Inspect cleaning area regularly.
  • Install curbing, berms or dikes around cleaning areas.

Liquid storage in above ground containers:

  • Maintain good integrity of all storage containers.
  • Install safeguards (such as berms) against accidental releases in the storage area.
  • Inspect storage tanks to detect potential leaks. Perform preventative maintenance.
  • Inspect piping systems for failures or leaks.
  • Train employees on proper filling and transfer procedures.

Improper connection with storm sewers:

  • Plug all floor drains if it is unknown whether the connection is to storm sewer or sanitary sewer. Alternatively, install a sump that is pumped regularly.
  • Update facility schematics to accurately reflect all plumbing connections.
  • Install a safeguard against vehicle washwaters and parts cleaning water entering the storm sewer unless permitted.
  • Maintain and inspect the integrity of all underground storage tanks; replace when necessary.